Leave Your Message
Products Categories
Featured Products

Products

SY135-8 SY135-9 SY155-10 SY155-11 KMX13R Distri...SY135-8 SY135-9 SY155-10 SY155-11 KMX13R Distri...
01

SY135-8 SY135-9 SY155-10 SY155-11 KMX13R Distri...

2025-12-15

1.Product Name:

Distributing valve

2.Part number:

KMX13R

3.Compatible For:

SY135-8 SY135-9 SY155-10 SY155-11

4.Leading time:

1-3 days

5.Packing way:

Neutral packing or SY Genuine Part Packing

view detail
SY365 SY375H SY395 SY485 SY500 SY550 Distributi...SY365 SY375H SY395 SY485 SY500 SY550 Distributi...
02

SY365 SY375H SY395 SY485 SY500 SY550 Distributi...

2025-12-15

1.Product Name:

Valve GP-BAN

2.Part number:

KMX32NA

3.Compatible For:

SY395 SY485 SY500 SY550

4.Leading time:

2-3 days

5.Packing way:

Neutral packing or SY Genuine Part Packing

view detail
Excavator Foot Pedal Valve For CAT E320GC 312GC...Excavator Foot Pedal Valve For CAT E320GC 312GC...
03

Excavator Foot Pedal Valve For CAT E320GC 312GC...

2025-12-14

Part number: 561-7001 490-1012

Product name:Foot pedal valve

Compatible for : E320GC 312GC 330GC

Packing way: Neutral packing 

view detail
Final Drive Sun Gear Spline Shaft Coupling Slee...Final Drive Sun Gear Spline Shaft Coupling Slee...
04

Final Drive Sun Gear Spline Shaft Coupling Slee...

2025-12-14

1.Product name:Motor Shaft

2.Part number:507-8035

3.Compatible for:CAT336D2 CAT340D2

4.Leading time:2-3 days

5.Packing way:Neutral packing or Caterpillar Original packing

view detail
XCMG XE26 Rotary pump Slewing Motor Swing Moto ...XCMG XE26 Rotary pump Slewing Motor Swing Moto ...
05

XCMG XE26 Rotary pump Slewing Motor Swing Moto ...

2025-12-13

1.Product Name:

Gear Box Assy

2.Part number:

4PH25C3478D  804017152

3.Compatible For:

XE26

4.Leading time:

1-3 days

5.Packing way:

Neutral packing or XE Genuine Part Packing

view detail
LG948E 950E 952E 956E Rotary pump Slewing Motor...LG948E 950E 952E 956E Rotary pump Slewing Motor...
06

LG948E 950E 952E 956E Rotary pump Slewing Motor...

2025-12-13

Daily Inspection

Visual inspection for leaks – Check all connections, seals, and housing for hydraulic oil leaks.

Monitor swing performance – Note any slowing, jerking, or loss of power during rotation.

Listen for unusual noises – Grinding, whining, or knocking sounds may indicate wear.

Check pump mounting bolts – Ensure they are tight and secure to prevent misalignment.

Inspect drive coupling – Look for cracks, wear, or damage in the flexible coupling.

Monitor hydraulic oil temperature – Abnormal heat may indicate pump inefficiency.

Check case drain flow – Excessive leakage from the drain line suggests internal wear.

Verify system pressure – Use gauges to ensure swing circuit pressure is within specifications.

Inspect electrical connections – For electronically controlled pumps, ensure connectors are clean and tight.

Observe swing drift – Excessive drift when stopped may indicate pump or valve issues.

Check breather/filter cap – Ensure it is clean and functioning to prevent contamination.

Routine Maintenance

Maintain proper oil level – Check and top up hydraulic oil regularly.

Use recommended hydraulic oil – Follow manufacturer’s viscosity and quality specifications.

Change hydraulic filters – Replace at specified intervals to prevent contamination.

Monitor oil cleanliness – Perform oil analysis if possible to detect early wear.

Check pump alignment – Misalignment causes premature wear and vibration.

Inspect suction line – Ensure it is free of restrictions or air leaks.

Bleed air from the system – If pump operation is noisy or erratic.

Clean the pump exterior – Remove dirt and debris to improve heat dissipation.

Lubricate linkage points – If the pump has external control linkages.

Record operating hours – Schedule maintenance based on service intervals.

Inspect cooling system – Ensure the oil cooler is clean and functional.

Operation & Monitoring

Avoid prolonged holding – Do not hold the swing against an obstacle for extended periods.

Prevent shock loads – Avoid sudden, jerky swing movements.

Allow warm-up time – Operate at low speed initially in cold conditions.

Monitor swing motor performance – Issues may originate from the motor, not the pump.

Check related valves – Inspect swing relief and control valves for proper function.

Avoid cavitation – Ensure proper inlet conditions and oil viscosity.

Train operators – Teach proper swing operation techniques to reduce pump stress.

Follow manufacturer’s guidelines – Adhere to all specific inspection and maintenance procedures.

view detail
Mini Construction Machinery Loader Bulldozer Ex...Mini Construction Machinery Loader Bulldozer Ex...
07

Mini Construction Machinery Loader Bulldozer Ex...

2025-12-13

1.Product Name:

Secondary Steering pump

2.Part number:

0804419691

3.Compatible For:

EZ08 EZ080 EZ083

4.Leading time:

2-3 days

5.Packing way:

Neutral packing or CAT Genuine Part Packing

view detail
708-2K-00113 708-2K-00114 708-2K-00115 PC800-8e...708-2K-00113 708-2K-00114 708-2K-00115 PC800-8e...
08

708-2K-00113 708-2K-00114 708-2K-00115 PC800-8e...

2025-12-13

Variable displacement axial piston pumps​ (dual).

Load sensing pressure-flow compensated (LSPC) system.

Swashplate angle control​ for output adjustment.

Hydraulic or electro-hydraulic servo control.

Closed-center load sensing (CLSS) circuit.

Power sharing between pumps.

Pressure cut-off (PCO) function.

Horsepower matching​ with the engine.

Cross-sensing​ between pump sections.

Displacement feedback mechanism.

High-pressure rotating groups.

Stationary valve plates.

Integral charge pump​ for make-up flow.

Case drain and flushing circuit.

Main system relief valves.

Anti-cavitation check valves.

Pressure compensator valves.

Flow compensator valves.

Load signal network (LS lines).

Pilot pressure supply circuit.

Pump controller (electronic or hydraulic).

Proportional solenoid valves​ (if equipped).

Pressure transducers​ for control feedback.

Mounting and drive system​ to the engine.

Breather and case drain ports.

Filtration system​ for charge and case drain oil.

Temperature management​ via case drain flow.

Efficiency optimization logic.

Fail-safe pressure and flow limiting.

Integrated diagnostic capability.

view detail
SK200-6 SK200-6E SK250-6 SK330-6E Joystick Cont...SK200-6 SK200-6E SK250-6 SK330-6E Joystick Cont...
09

SK200-6 SK200-6E SK250-6 SK330-6E Joystick Cont...

2025-12-13

1.Product Name:

Joystick Control Base

2.Part number:

YT30V00008F2

3.Compatible For:

SK200-6 SK200-6E SK250-6 SK330-6E

4.Leading time:

2-3 days

5.Packing way:

Neutral packing or CAT Genuine Part Packing

6.Price:

USD147

view detail
XPower Hydraulic Parts PVSD2-17E PSVD2-17E-23 P...XPower Hydraulic Parts PVSD2-17E PSVD2-17E-23 P...
10

XPower Hydraulic Parts PVSD2-17E PSVD2-17E-23 P...

2025-12-13

1.Product name:Gear pump
2.Part number:PVSD2-17E
3.Compatible for:PSVD2-21 PSVD2-27E
4.Leading time:2-3 days
5.Packing way:CAT original Packing

 

view detail
Ignition Switch 194215-52110 Construction Machi...Ignition Switch 194215-52110 Construction Machi...
11

Ignition Switch 194215-52110 Construction Machi...

2025-12-13

1.Product name:ignition switch
2.Part number:194215-52110
3.Compatible for:FX20 FX22 FX28 FX32 FX32D FX17 FX18
4.Leading time:2-3 days
5.Packing way:Neutral packing or customization packing

view detail
Product Code 12025701 SY330H 365H 375H 485H 550...Product Code 12025701 SY330H 365H 375H 485H 550...
12

Product Code 12025701 SY330H 365H 375H 485H 550...

2025-12-13

Immediate engine shutdown

Emergency power cut-off

Critical hazard prevention

Hydraulic system deactivation

Life-threatening situation response

Uncontrollable machine motion stop

Fire emergency response

Electrical failure safety measure

Operator injury prevention

Bystander protection

Equipment damage prevention

Runaway machine control

Entanglement emergency release

Collision avoidance activation

Fuel leak emergency response

Hydraulic line rupture response

Electrical fire containment

System-wide safety override

Maintenance safety lockout

Training simulation emergency

Unauthorized operation prevention

Emergency evacuation facilitation

First responder safety enable

Catastrophic failure mitigation

Environmental hazard containment

Secondary damage prevention

Regulatory compliance requirement

ISO safety standard compliance

Safety circuit master control

Ultimate safety backup system

view detail
M2X63 Excavator Swing Motor SY135 CLG915 DH130 ...M2X63 Excavator Swing Motor SY135 CLG915 DH130 ...
13

M2X63 Excavator Swing Motor SY135 CLG915 DH130 ...

2025-12-12

Variable displacement axial piston pumps​ (dual).

Load sensing pressure-flow compensated (LSPC) system.

Swashplate angle control​ for output adjustment.

Hydraulic or electro-hydraulic servo control.

Closed-center load sensing (CLSS) circuit.

Power sharing between pumps.

Pressure cut-off (PCO) function.

Horsepower matching​ with the engine.

Cross-sensing​ between pump sections.

Displacement feedback mechanism.

High-pressure rotating groups.

Stationary valve plates.

Integral charge pump​ for make-up flow.

Case drain and flushing circuit.

Main system relief valves.

Anti-cavitation check valves.

Pressure compensator valves.

Flow compensator valves.

Load signal network (LS lines).

Pilot pressure supply circuit.

Pump controller (electronic or hydraulic).

Proportional solenoid valves​ (if equipped).

Pressure transducers​ for control feedback.

Mounting and drive system​ to the engine.

Breather and case drain ports.

Filtration system​ for charge and case drain oil.

Temperature management​ via case drain flow.

Efficiency optimization logic.

Fail-safe pressure and flow limiting.

Integrated diagnostic capability.

view detail
Kubota U08 10-3 A55F9H8-R89830 Hydraulic pump H...Kubota U08 10-3 A55F9H8-R89830 Hydraulic pump H...
14

Kubota U08 10-3 A55F9H8-R89830 Hydraulic pump H...

2025-12-12

Variable displacement axial piston pumps​ (dual).

Load sensing pressure-flow compensated (LSPC) system.

Swashplate angle control​ for output adjustment.

Hydraulic or electro-hydraulic servo control.

Closed-center load sensing (CLSS) circuit.

Power sharing between pumps.

Pressure cut-off (PCO) function.

Horsepower matching​ with the engine.

Cross-sensing​ between pump sections.

Displacement feedback mechanism.

High-pressure rotating groups.

Stationary valve plates.

Integral charge pump​ for make-up flow.

Case drain and flushing circuit.

Main system relief valves.

Anti-cavitation check valves.

Pressure compensator valves.

Flow compensator valves.

Load signal network (LS lines).

Pilot pressure supply circuit.

Pump controller (electronic or hydraulic).

Proportional solenoid valves​ (if equipped).

Pressure transducers​ for control feedback.

Mounting and drive system​ to the engine.

Breather and case drain ports.

Filtration system​ for charge and case drain oil.

Temperature management​ via case drain flow.

Efficiency optimization logic.

Fail-safe pressure and flow limiting.

Integrated diagnostic capability.

view detail
ZAX330-1 ZAX330-3 ZAX350 M5X180CHB-10A-64B 9236...ZAX330-1 ZAX330-3 ZAX350 M5X180CHB-10A-64B 9236...
15

ZAX330-1 ZAX330-3 ZAX350 M5X180CHB-10A-64B 9236...

2025-12-12

Daily Inspection

Visual inspection for leaks – Check all connections, seals, and housing for hydraulic oil leaks.

Monitor swing performance – Note any slowing, jerking, or loss of power during rotation.

Listen for unusual noises – Grinding, whining, or knocking sounds may indicate wear.

Check pump mounting bolts – Ensure they are tight and secure to prevent misalignment.

Inspect drive coupling – Look for cracks, wear, or damage in the flexible coupling.

Monitor hydraulic oil temperature – Abnormal heat may indicate pump inefficiency.

Check case drain flow – Excessive leakage from the drain line suggests internal wear.

Verify system pressure – Use gauges to ensure swing circuit pressure is within specifications.

Inspect electrical connections – For electronically controlled pumps, ensure connectors are clean and tight.

Observe swing drift – Excessive drift when stopped may indicate pump or valve issues.

Check breather/filter cap – Ensure it is clean and functioning to prevent contamination.

Routine Maintenance

Maintain proper oil level – Check and top up hydraulic oil regularly.

Use recommended hydraulic oil – Follow manufacturer’s viscosity and quality specifications.

Change hydraulic filters – Replace at specified intervals to prevent contamination.

Monitor oil cleanliness – Perform oil analysis if possible to detect early wear.

Check pump alignment – Misalignment causes premature wear and vibration.

Inspect suction line – Ensure it is free of restrictions or air leaks.

Bleed air from the system – If pump operation is noisy or erratic.

Clean the pump exterior – Remove dirt and debris to improve heat dissipation.

Lubricate linkage points – If the pump has external control linkages.

view detail
Hydraulic Main Pump K5V212 XE LiuGong Zoomlion ...Hydraulic Main Pump K5V212 XE LiuGong Zoomlion ...
16

Hydraulic Main Pump K5V212 XE LiuGong Zoomlion ...

2025-12-12

Variable displacement axial piston pumps​ (dual).

Load sensing pressure-flow compensated (LSPC) system.

Swashplate angle control​ for output adjustment.

Hydraulic or electro-hydraulic servo control.

Closed-center load sensing (CLSS) circuit.

Power sharing between pumps.

Pressure cut-off (PCO) function.

Horsepower matching​ with the engine.

Cross-sensing​ between pump sections.

Displacement feedback mechanism.

High-pressure rotating groups.

Stationary valve plates.

Integral charge pump​ for make-up flow.

Case drain and flushing circuit.

Main system relief valves.

Anti-cavitation check valves.

Pressure compensator valves.

Flow compensator valves.

Load signal network (LS lines).

Pilot pressure supply circuit.

Pump controller (electronic or hydraulic).

Proportional solenoid valves​ (if equipped).

Pressure transducers​ for control feedback.

Mounting and drive system​ to the engine.

Breather and case drain ports.

Filtration system​ for charge and case drain oil.

Temperature management​ via case drain flow.

Efficiency optimization logic.

Fail-safe pressure and flow limiting.

Integrated diagnostic capability.

view detail